The Keysight MSOX3054A (Agilent) is a four-channel model in the InfiniiVision 3000 X-Series. Engineered with breakthrough technology this upgradable oscilloscope provides superior performance and functionality. Its unique 5-instruments-in-one design delivers more scope for the same budget.
Features and Specifications of the Keysight MSOX3054A Oscilloscope include:
Features of the Agilent MSOX3054A include:
-
One million waveforms per second update rate
-
MegaZoom IV smart memory technology
-
Large 8.5-inch WVGA display
-
Optional segmented memory
-
Industry’s first 5-instruments-in-1:
-
Oscilloscope
-
Digital channels
-
Built-in 20 MHz function/arbitrary waveform generator with modulation
-
Integrated digital voltmeter
-
Protocol analyzer
-
Investment protection with Industry’s only fully-upgradable oscilloscope, including bandwidth up to 1 GHz
-
Industry’s leading applications solution
Specifications of the Keysight MSOX3054A (Agilent) include:
-
Bandwidth (-3 dB): 500 MHz
-
Calculated rise time (10 – 90%): ≤ 700 ps
-
Input channels:
-
4 analog channels
-
16 digital channels
-
Maximum sample rate:
-
4 GSa/s half channel
-
2 GSa/s all channel
-
Maximum memory depth:
-
Standard 2 Mpts
-
Optional 4 Mpts
-
Optional segment memory
-
Display size and type: 8.5 WVGA display
-
Waveform update rate: > 1 million waveforms per second
-
Number of active probes supported: In general, one for 2-channel models
-
Vertical system analog channels:
-
Hardware bandwidth limits: Approximately 20 MHz (selectable)
-
Input coupling: AC, DC
-
Input impedance: Selectable:
-
1 MΩ ± 1% (14 pF)
-
50 Ω ± 1.5%
-
Input sensitivity range: 1mV/div to 5 V/div (1 MΩ and 50 Ω)
-
Vertical resolution: 8 bits (measurement resolution is 12 bits with averaging)
-
Maximum input voltage:
-
300 Vrms, 400 Vpk
-
Transient overvoltage 1.6 kVpk
-
With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
-
Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
-
DC vertical accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
-
DC vertical gain accuracy: ± 2.0% full scale
-
DC vertical offset accuracy: ± 0.1 div ± 2 mV ± 1% of offset setting
-
Channel-to-channel isolation: > 100:1 from DC to maximum specified bandwidth of each model (measured with same V/div and coupling on channels)
-
Offset range:
-
± 2 V (1 mV/div to 200 mV/div)
-
± 50 V (> 200 mV/div to 5 mV/div)
-
Vertical system digital channels:
-
Digital input channels: 16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
-
Thresholds: Threshold per pod
-
Threshold selections: TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
-
User-defined threshold range: ± 8.0 V in 10 mV steps
-
Maximum input voltage: ± 40 V peak CAT l; transient overvoltage 800 Vpk
-
Threshold accuracy: ± (100 mV + 3% of threshold setting)
-
Maximum input dynamic range: ± 10 V about threshold
-
Minimum voltage swing: 5 mVpp
-
Input impedance: 100 kΩ ± 2% at probe tip
-
Input capacitance: ~8 pF
-
Vertical resolution: 1 bit
-
Horizontal system analog channels:
-
Time base range: 1 Ns/div to 50 s/div
-
Time base accuracy: 25 ppm ± 5 ppm per year (aging)
-
Time base delay time range:
-
Pre-trigger: Greater of 1 screen width or 250 μs
-
Post-trigger: 1 s to 500 s
-
Channel-to-channel deskew range: ± 100 ns
-
Δ Time accuracy (using cursors): ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps
-
Modes: Main, zoom, roll, XY
-
XY:
-
On channels 1 and 2 only, Z Blanking on ext trigger input, 1.4 V threshold
-
Bandwidth: Maximum bandwidth
-
Phase error at 1 MHz: < 0.5 degree
-
Horizontal system digital channels:
-
Minimum detectable pulse width: 5 ns
-
Channel-to-channel skew:
-
2 ns (typical)
-
3 ns (maximum)
-
Aquisition system:
-
Maximum analog channels sample rate:
-
4 GSa/s half channel interleaved
-
2 GSa/s all channel
-
Maximum analog channels record length:
-
2 Mpts half channel interleaved, 1 Mpts all channel (standard)
-
4 Mpts half channel interleaved, 2 Mpts all channel (optional with DSOX3MEMUP (-040))
-
Maximum duration of time captured at highest sampling rate (all analog channels): 500 us with 4M memory upgrade
-
Maximum digital channels sample rate: 1 GSa/s
-
Maximum digital channels record length:
-
1 Mpts (standard with digital channels only)
-
2 Mpts (optional with DSOX3MEMUP – with digital channels only)
-
Modes:
-
Normal: Default mode
-
Peak detect: Capture glitches as narrow as 250 ps at all time base settings
-
Averaging: Selectable from 2, 4, 8, 16, 64, … to 65,536
-
High resolution:
-
Real time boxcar averaging reduces random noise and effectively increases vertical resolution
-
12 bits of resolution when ≥ 10 μs/div at 4 GSa/s
-
or ≥ 20-μs/div at 2 GSa/s
-
Segmented:
-
Segmented memory optimizes available memory for data streams that have long dead times between activity
-
Maximum segments = 1000
-
Re-arm time = 1 μs (minimum time between trigger events)
-
Trigger system:
-
Trigger sources: Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
-
Trigger modes:
-
Normal (triggered): requires trigger event for scope to trigger
-
Auto : triggers automatically in absence of trigger event
-
Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode
-
Force: front panel button that forces a trigger
-
Trigger coupling:
-
DC: DC coupled trigger
-
AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal);
-
High frequency reject: cutoff frequency ~ 50 kHz
-
Low frequency reject: cutoff frequncy ~ 50 kHz
-
Noise reject:
-
Selectable OFF or ON
-
Decreases sensitivity 2x
-
Trigger holdoff range: 40 ns to 10.00 s
-
Trigger sensitivity:
-
Internal: < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
-
External:
-
200 mVpp from DC to 100 MHz
-
350 mVpp 100 MHz to 200 MHz
-
Trigger level range:
-
Any channel: ± 6 div from center screen
-
External: ± 8 V