TLD034

Static Bend Radius: 1.60mm
Weight: 0.003Kg/m
Installation & Operating Temperature Range: -55℃~+125℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Materials
1 Inner Conductor 0.203 SPC
2 Dielectric 0.660 PTFE
3 Outer Conductor 0.864 Immersion Tin Copper / Cu-Sn-Zn Alloy

Mechanical & Environmental Specifications

Static Bend Radius: 1.60mm

Weight: 0.003Kg/m

Installation & Operating Temperature Range: -55℃~+125℃

Electrical Specifications

Frequency Range: 40GTLZ

Cutoff Frequency: 154GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 70%

Shielding Effectiveness: >165dB

Voltage Power: 100V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000 26500 40000
Attenuation (dB/100m) 1.6 2.2 2.8 4.0 4.6 5.2 5.8 7.1 8.7 11.0
Avg. Power (kW) 0.056 0.039 0.032 0.022 0.019 0.017 0.015 0.012 0.010 0.008
K1= 0.049002
K2= 0.000029
Calculation= K1* √FMhz+K2*FMHz

Features & Advantages

Low Loss

Low VSWR

Low Passive Intermodulation (-155dbc)

Typical Applications

RF Module Internal Interconnection

Precision Instruments Internal Interconnection

Small, Complex Installation Space