Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 0.29 | SPC |
2 | Dielectric | 0.95 | PTFE |
3 | Outer Conductor | 1.22 | Immersion Tin Copper / Cu-Sn-Zn Alloy |
Mechanical & Environmental Specifications
Static Bend Radius: 4.2mm
Weight: 0.004Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 40GTLZ
Cutoff Frequency: 100GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 70%
Shielding Effectiveness: >165dB
Voltage Power: 100V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 |
Attenuation (dB/100m) | 1.1 | 1.6 | 2.0 | 2.9 | 3.4 | 3.8 | 4.3 | 5.2 | 6.5 | 8.2 |
Avg. Power (kW) | 0.059 | 0.041 | 0.033 | 0.023 | 0.020 | 0.018 | 0.016 | 0.013 | 0.010 | 0.008 |
K1= | 0.035016 | |||||||||
K2= | 0.000029 | |||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Low Passive Intermodulation (-155dbc)
Typical Applications
RF Module Internal Interconnection
Precision Instruments Internal Interconnection
Small, Complex Installation Space