Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 0.53 | SPC |
2 | Dielectric | 1.68 | PTFE |
3 | Outer Conductor | 2.18 | Immersion Tin Copper / Cu-Sn-Zn Alloy |
Mechanical & Environmental Specifications
Static Bend Radius: 7mm
Weight: 0.021Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 40GTLZ
Cutoff Frequency: 59GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 70%
Shielding Effectiveness: >165dB
Voltage Power: 150V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 |
Attenuation (dB/100m) | 64.9 | 93.1 | 115.2 | 166.6 | 194.7 | 219.9 | 247.6 | 304.9 | 379.9 | 482.7 |
Avg. Power (kW) | 0.256 | 0.179 | 0.144 | 0.100 | 0.085 | 0.076 | 0.067 | 0.055 | 0.044 | 0.034 |
K1= | 1.985320 | |||||||||
K2= | 0.002140 | |||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Low Passive Intermodulation (-155dbc)
Typical Applications
RF Module Internal Interconnection
Precision Instruments Internal Interconnection
Small, Complex Installation Space