Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 1.78 | SPC |
2 | Dielectric | 5.33 | PTFE |
3 | Outer Conductor | 6.35 | Immersion Tin Copper / Cu-Sn-Zn Alloy |
Mechanical & Environmental Specifications
Static Bend Radius: 32mm
Weight: 0.136Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 18GTLZ
Cutoff Frequency: 19GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 70%
Shielding Effectiveness: >165dB
Voltage Power: 2200V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 |
Attenuation (dB/100m) | 18.3 | 26.2 | 32.4 | 47.0 | 54.9 | 62.1 | 69.9 | 86.1 |
Avg. Power (kW) | 1.878 | 1.309 | 1.058 | 0.730 | 0.625 | 0.553 | 0.491 | 0.398 |
K1= | 0.557600 | |||||||
K2= | 0.000630 | |||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Low Passive Intermodulation (-155dbc)
Typical Applications
RF Module Internal Interconnection
Precision Instruments Internal Interconnection
Small, Complex Installation Space