Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 1.02 | Solid SPC |
2 | Dielectric | 2.92 | LD-PTFE |
3 | Inner Shield | 3.10 | SPC Strip |
4 | Interlayer | 3.38 | LD-PTFE |
5 | Outer Shield | 3.95 | SPC Braid |
6 | Jacket | 5.20 | Blue PUR |
Mechanical & Environmental Specifications
Static Bend Radius: 26mm
Dynamic Bend Radius: 52mm
Weight: 0.058Kg/m
Installation & Operating Temperature Range: -55℃~+85℃
Electrical Specifications
Frequency Range: 26.5GTLZ
Cutoff Frequency: 35GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 70%
Shielding Effectiveness: >90dB
Voltage Power: 500V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 |
Attenuation (dB/100m) | 38.5 | 55.9 | 69.8 | 103.2 | 121.9 | 139.0 | 157.9 | 198.0 | 252.1 |
Avg. Power (kW) | 0.149 | 0.103 | 0.082 | 0.056 | 0.047 | 0.041 | 0.036 | 0.029 | 0.023 |
K1= | 1.13660C | ||||||||
K2= | 0.002530 | ||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Bending, Shake, Torsion & Pull resistance
Typical Applications
System Test
High Throughput RF Production Testing
System Interconnection