TLN460

Static Bend Radius: 25mm
Dynamic Bend Radius: 50mm
Weight: 0.057Kg/m
Installation & Operating Temperature Range: -55℃~+85℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Materials
1 Inner Conductor 1.02 Solid SPC
2 Dielectric 3.07 LD-PTFE
3 Inner Shield 3.27 SPC Strip
4 Interlayer 3.43 Aluminum Foil
5 Outer Shield 3.94 SPC Braid
6 Jacket 5.00 Rat-proof PUR

Mechanical & Environmental Specifications

Static Bend Radius: 25mm

Dynamic Bend Radius: 50mm

Weight: 0.057Kg/m

Installation & Operating Temperature Range: -55℃~+85℃

Electrical Specifications

Frequency Range: 18GTLZ

Cutoff Frequency: 35GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 76%

Shielding Effectiveness: >70dB

Voltage Power: 1000V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 16000 18000
Attenuation (dB/100m) 35.4 50.4 62.0 88.8 103.2 116.0 129.9 148.7 158.3
Avg. Power (kW) 0.199 0.140 0.113 0.079 0.068 0.061 0.054 0.047 0.044
K1= 1.099485
K2= 0.000602
Calculation= K1* √FMhz+K2*FMHz

Features & Advantages

More Than 20 Years’ Life Outdoors

Low Loss

Cost-effective

Typical Applications

Armored Vehicles, Tank and Mobile Vehicles Antenna

Military Radio Communications

Warship Telecommunication Equipments Interconnection

Phased Array Radar Antenna

Telecommunication Base Stations Interconnection