Cable Construction Specifications
| Description | Dimensions (mm) | Materials | |
| 1 | Inner Conductor | 0.91 | |
| 2 | Dielectric | – | |
| 3 | Inner Shield | 2.95 | |
| 4 | Interlayer | – | |
| 5 | Outer Shield | 3.35 | |
| 6-7 | Jacket | 4.00 |
Mechanical & Environmental Specifications
Static Bend Radius: 20mm
Dynamic Bend Radius: 40mm
Weight: 0.040Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Withstand Temperature: +400℃ over 400 seconds
Electrical Specifications
Frequency Range: 40GTLZ
Cutoff Frequency: 56GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 83%
Shielding Effectiveness: >90dB
Voltage Power: 100V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
| Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 |
| Attenuation (dB/100m) | 41.2 | 58.6 | 72.0 | 102.9 | 119.4 | 134.0 | 149.9 | 182.3 | 223.8 | 279.1 |
| Avg. Power (kW) | 0.509 | 0.358 | 0.291 | 0.204 | 0.176 | 0.156 | 0.140 | 0.115 | 0.094 | 0.075 |
| K1= | 1.285317 | |||||||||
| K2= | 0.000550 | |||||||||
| Calculation= | K1* √FMhz+K2*FMHz | |||||||||
Features & Advantages
Low Loss
Low VSWR
Withstand High Temperature
Typical Applications
Withstand Extremely High Temperature Test
Missiles Telecommunications