Used Oscilloscope Agilent DSOX4104A

●One million waveforms per second update rate
●MegaZoom IV smart memory technology
●Standard segmented memory
●Large 12.1-inch capacitive touch display

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

The Keysight DSOX4104A is a four-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The DSOX4104A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.

Features and Specifications of:

Features of:

●One million waveforms per second update rate

●MegaZoom IV smart memory technology

●Standard segmented memory

●Large 12.1-inch capacitive touch display

●Interface designed for touch

●Innovative InfiniiScan Zone touch triggering

●5 instruments in 1, with full upgradability, including bandwidth:

oOscilloscope  

oLogic analyzer (MSO) 

oSerial protocol analyzer, including USB (optional)

oWaveGen 20 MHz dual channel arbitrary/function generator (optional)

oDigital voltmeter (DVM) option:

■With 3-digit voltage

■With 5-digit frequency counter measurements

Specifications of the Keysight  DSOX4104A (Agilent) include:

●Bandwidth (-3 dB):  1 GHz

●All-channel real-time bandwidth:  1 GHz

●Calculated rise time (10 – 90%):  ≤ 450 ps

●Input channels:  4 analog

●Maximum sample rate:

o5 GSa/s half channel

o2.5 GSa/s all channel

●Maximum memory depth:  Standard 4 Mpts, standard segmented memory

●Display size and type:  12.1-inch high-definition capacitive touch display

●Waveform update rate:  > 1 million waveforms per second

●System bandwidth with N2894A standard passive probe: 700 MHz

●Vertical system analog channels:

oHardware bandwidth limits:  Approximately 20 MHz (selectable)

oInput coupling:  AC, DC

oInput impedance:  Selectable:  

■1 MΩ ± 1% (16 pF)

■50 Ω ± 1.5%

oInput sensitivity range:  

■1 mV/div to 5 V/div (1 MΩ)

■1 mV/div to 1 V/div (50 ohm)

oVertical resolution:  8 bits (measurement resolution is 12 bits with averaging)

oMaximum input voltage:

■300 Vrms, 400 Vpk

■Transient overvoltage 1.6 kVpk

■With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms

■Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk

oDC vertical gain accuracy: ± 2.0% full scale

oDC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting

oChannel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model

oOffset range:

■± 5 V (< 10 mV/div)

■± 20 V (10 to 200 mV/div)

■± 75 V (> 200 mV/div)

●Vertical system digital channels:

oDigital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)

oThresholds: Threshold per pod

oThreshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)

oUser-defined threshold range:  ± 8.0 V in 10 mV steps

oMaximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk

oThreshold accuracy:  ± (100 mV + 3% of threshold setting)

oMaximum input dynamic range:  ± 10 V about threshold

oMinimum voltage swing:  500 mVpp

oInput impedance:  100 kΩ ± 2% at probe tip

oInput capacitance:  ~8 pF

oVertical resolution: 1 bit

●Horizontal system analog channels:  

oTime base range:  2 ns/div to 50 s/div

oTime base accuracy:  ± 10 ppm

oTime base delay time range:

■Pre-trigger:  Greater of 1 screen width or 200 μs (400 μs in interleaving mode)

■Post-trigger: 1 s to 500 s

oChannel-to-channel deskew range:  ± 100 ns

oΔ Time accuracy (using cursors):  ± 0.001% of reading ± 0.16% screen width ± 30pS

oModes:  Main, zoom, roll, XY

oXY:

■On channels 1 and 2 only

■Z Blanking on ext trigger input, 1.4 V threshold  

■Bandwidth:  Maximum bandwidth

■Phase error at 1 MHz: < 0.5 degree

■Time base: 200 ns/div to 50 ms/div

●Horizontal system digital channels:  

oMinimum detectable pulse width:  2 ns

oChannel-to-channel skew:

■2 ns (typical)

■3 ns (maximum)

●Aquisition system:

oMaximum analog channels sample rate:  

■5 GSa/s half channel interleaved

■2.5 GSa/s all channel

oMaximum analog channels record length:

■4 Mpts half channel interleaved

■2 Mpts all channel

oModes:

■Normal:  Default mode

■Peak detect:  Capture glitches as narrow as 200 ps at all time base settings

■Averaging:  Selectable from 2, 4, 8, 16, 64, … to 65,536

■High resolution:

■Real time boxcar averaging reduces random noise and effectively increases vertical resolution

■12 bits:  ≥ 50 μs/div

■11 bits:  ≥ 20 μs/div

■10 bits:  ≥ 10 μs/div

■9 bits:  ≥ 5 μs/div

■Segmented:

■Segmented memory optimizes available memory for data streams that have long dead times between activity

■Maximum segments = 1000

■Re-arm time = 1 μs (minimum time between trigger events)

■Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)

■Roll:  

■Displays the waveform moving across the screen from right to left

■Available at the time base 50 ms/div or slower

●Trigger system:

oTrigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)

oTrigger modes:

■Normal: Requires trigger event for scope to trigger

■Auto : Triggers automatically in absence of trigger event

■Single:

■Front panel button that triggers only once on a trigger event

■Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode

■Force:  Front panel button that forces a trigger

oTrigger coupling:  

■DC: DC coupled trigger

■AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)

■High frequency reject:  Cutoff frequency ~ 50 kHz

■Low frequency reject:  Cutoff frequency ~ 50 kHz 

■Noise reject:

■Adds hysteresis to the trigger circuitry

■Selectable OFF or ON

■Decreases sensitivity 2x

oTrigger holdoff range: 40 ns to 10.00 s  

oTrigger sensitivity:

■Internal:

■< 10 mV/div: greater of 1 div or 5 mV

■≥ 10 mV/div: 0.6 div

■External:

■± 1.6 V:  

■40 mVpp DC to 100 MHz

■70 mVpp 100 MHz to 200 MHz

■± 8 V:  

■200 mVpp DC to 100 MHz

■350 mVpp 100 MHz to 200 MHz

oTrigger level range:

■Any channel:  ± 6 div from center screen

■External:  

■± 8 V range = ± 8 V

■± 1.6 V range = ± 1.6 V

●Connectivity:

oUSB 2.0 hi-speed host port:

■x3 ports, 2 front and one rear panel

■Supports memory devices, printers, keybords and mice

oUSB 2.0 hi-speed device port:

■One port on rear panel

■USB Test & Measurement Class (USBTMC) compatible

oLAN port:

■10/100Base-T port on rear panel

■LXI IPv6 extended function

oWeb remote control:  VNC Web interface (via major Web browsers)

oVideo out port:  

■SVGA out on rear panel

■Connect oscilloscope display to an external monitor or projector

oGPIB port:  N4865A GPIB-to-LAN adapter (optional)

o10 MHz out/in:  

■BNC connector on the rear panel

■Suported modes:  Off, 10 MHz out, or reference signal mode (10 MHz in)

oTrigger out:  

■BNC connecter on the rear panel 

■Supported modes:  triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse