When the Agilent 81104A Pulse Pattern Generator Mainframe is combined with one or two Agilent 81105A output modules (single and/or dual channel) builds on the performance of the 81101A and is also backward-compatible. Each Agilent 81104A single-channel Pulse Pattern Generator requires one Agilent 81105A output module. For the dual-channel configuration, two Agilent 81105A output modules are required. If two Agilent 81105A Output modules are available, the outputs can be added. This allows elaborate pulse shapes for simulating glitches, testing clock-recovery circuits or generating 3- or 4-level codes.
The Agilent 81104A produces all the standard pulses and digital patterns needed to test current logic technologies. By using the internal channel addition feature provided by the optional second channel, multi-level and multi-timing signals can be produced. The Agilent 81104A Pulse Pattern Generator provides high quality signals and flexibility that meet virtually all application needs.
Features and Specifications of:
●Features:
oSingle-/dual-channel pulse pattern generator mainframe
oExtends the frequency range and adds RZ/NRZ pattern capability up to 16 kbit per channel
oAn NRZ strobe channel provides:
■a trigger at arbitrary points in the pattern
■or can be used as an additional pattern source
oTriggerable / PLL operation selectable
oPulse / burst / pattern modes selectable
oVariable transition times
oBNC outputs: single-ended
oDropout and glitch free timing change
oChannel-add and 1000 Ohm source modes:
■Each operate up to about 60 MHz
■Combined, the maximum speed is about 15 MHz.
oClean, accurate pulses with excellent repeatability providing reliable measurements
oFeatures such as the clear graphical display, autoset, help, store / recall, preset TTL / ECL levels, selectable units (such as current / voltage, width / duty-cycle), and load compensation ensure a high level of convenience that make it easy to use
oInternal channel addition:
■Provides multi-level and multi-timing signals to be obtained
■Variable pulse parameters in pattern mode as well as in pulse mode
■Synchronously triggerable
■Simulation of reflections / distortions
■Three / four-level codes
oFlexible pulses or patterns for digital designs:
■Pattern mode including pseudo-random binary sequence
■Outputs of dual-channel instruments can be added (analog or EXOR, depending on model)
■User-retrofittable channels
■Upward compatibility
■Individual solutions for frequencies up to 50, 80, 165, 330, 400, and 660 MHz
■100% form / fit compatibility
●Specifications:
oMainframe: 81104A
oChannel Model: 81105A, 80 MHz, 10 V
o# of channels: 1 or 2
oSingle or dual-channel: Requires 1 or 2 output Agilent 81105A modules
oFrequency Range: 1 MHz – 80 MHz
oVariable delay range: 12.5 ns – 999.5 s
oPeriod RMS – jitter: 0.00 s – 999.5 s
oWidth Range: 6.25 ns – 9.995 s
oAmplitude Range: 100 mV – 20.0 V (Depends on selected impedance (all other values for 50 Ω source impedance into 50 Ω load))
oTransition Time Range (10/90): 3.00 ns – 200 ms
oSource Impedance: 50 Ω or 1 kΩ