Used SourceMeter Keithley 2601

●Aprecision power supply
●A true current source
●A 51/2-digit multimeter
●A voltage or current pulse generator with measurement

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

The Keithley 2601 SourceMeter lets you make precision DC, pulse, and low frequency AC source-measure tests faster, easier, and more economically than before. The Keithley 2601 offers two to four times the test speed of competitive products for I-V functional testing by combining:

●Keithley’s high speed, third-generation Source-Measure Unit (SMU) design

●An embedded Test Script Processor (TSP™)

●TSP-Link™, a fast triggering and inter-unit communication bus

The Keithley 2601 has a single 40W, 3A channel and is electrically isolated to ensure high measurement integrity and wiring flexibility. The Keithley 2601 packs many instruments into a small package, including:

●Aprecision power supply

●A true current source

●A 51/2-digit multimeter

●A voltage or current pulse generator with measurement

●A low frequency arbitrary waveform generator

●An electronic load

●A trigger controller

Features and Specifications of:

●TSP-Link allows connection of multiple 2600 series instruments in a master/slave config allowing unlimited scalability

●On-board Test Script Processor processes and runs complex sequences from the instrument – gives you up to 10X greater throughput

oallows creation of custom measurement functions for components such as varistors, diodes and BJTs/FETs, or algorithm based tests like I-V sweeps with power compliance, linearity and latch-up test sequences, and thermal response tests.

●Store up to 50,000 lines of TSP code and more than 200,000 readings in 16MB of nonvolatile memory.

●Measure I and V at >10,000 readings/s. Execute a full source-measure cycle in just 200µs

●Ensure repeatable timing and high throughput with the high speed auto-ranging function.

●GPIB, RS-232 and 14-bit digital I/O interface ports are standard

●Current measure range (per channel) 1pA to 3A

●Current source range (per channel) 5pA to 3A

●Basic current programming accuracy 0.03%

●Basic current measurement accuracy 0.02%

●Voltage measure range (per channel) 1µV to 40V

●Voltage source range (per channel) 5µV to 40V

●Basic voltage programming accuracy 0.02%

●Basic voltage measurement accuracy 0.015%

●Readings to memory 10,000/s

●Sweep source change and reading to memory 5,500/s

●Sweep source change and reading to GPIB 3,600/s

●Spot readings to GPIB 1,100/s

●Spot source change and reading to GPIB 880/s

●Pulse capability 200µs minimum source/measure pulse