Cable Construction Specifications
| Description | Dimensions (mm) | Material | |
| 1 | Inner Conductor | 3.00 | Solid SPC |
| 2 | Dielectric | 8.24 | LD-PTFE |
| 3 | Outer Conductor | – | SPC Strip |
| 4 | Outer Shield | 9.20 | SPC Braid |
| 5 | Jacket | 10.00 | Grey PFA or Custom |
Mechanical & Environmental Specifications
Static Bend Radius: 41mm
Dynamic Bend Radius: 83mm
Weight: 0.206Kg/m
Installation & Operating Temperature Range: -55℃~+165℃
Electrical Specifications
Frequency Range: 10GTLZ
Cutoff Frequency: 13.5GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 83%
Shielding Effectiveness: >90dB
Voltage Power: 3000V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
| Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 16000 | 18000 |
| Attenuation (dB/100m) | 10.4 | 15.0 | 18.7 | 21.8 | 24.6 | 27.2 | 31.9 | 36.1 | |
| Avg.Power (kW) | 2.289 | 1.590 | 1.281 | 1.097 | 0.972 | 0.880 | 0.750 | 0.662 | |
| K1= | 0.316177 | ||||||||
| K2= | 0.000448 | ||||||||
| Calculation = | K1* √FMhz+K2*FMHz | ||||||||
Features & Advantages
Phase Change vs Temperature (<750PPM@-55℃-+85℃)
Low Loss
High Power
Low Passive Intermodulation (-155dbc)
Light Weight
Typical Applications
Phased Array Radar
Aviation Electronics
Electronic Confrontation
On Any Low Loss & Phase Occasions