Cable Construction Specifications
Description | Dimensions (mm) | Material | |
1 | Inner Conductor | 2.44 | Solid SPC |
2 | Dielectric | 6.50 | LD-PTFE |
3 | Outer Conductor | 6.90 | SPC Strip |
4 | Outer Shield | 7.65 | SPC Braid |
5 | Jacket | 8.30 | Grey PFA or Custom |
Mechanical & Environmental Specifications
Static Bend Radius: 41mm
Dynamic Bend Radius: 83mm
Weight: 0.162Kg/m
Installation & Operating Temperature Range: -55℃~+165℃
Electrical Specifications
Frequency Range: 18GTLZ
Cutoff Frequency: 18GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 83%
Shielding Effectiveness: >90dB
Voltage Power: 2500V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 16000 | 18000 |
Attenuation (dB/100m) | 13.3 | 18.9 | 23.4 | 33.6 | 39.1 | 44.1 | 49.5 | 56.9 | 60.6 |
Avg.Power (kW) | 1.894 | 1.326 | 1.075 | 0.747 | 0.641 | 0.569 | 0.507 | 0.442 | 0.414 |
K1= | 0.408997 | ||||||||
K2= | 0.000320 | ||||||||
Calculation = | K1* √FMhz+K2*FMHz |
Features & Advantages
Phase Change vs Temperature (<750PPM@-55℃-+85℃)
Low Loss
High Power
Low Passive Intermodulation (-155dbc)
Light Weight
Typical Applications
Phased Array Radar
Aviation Electronics
Electronic Confrontation
On Any Low Loss & Phase Occasions