TLF086

Static Bend Radius: 7mm
Weight: 0.021Kg/m
Installation & Operating Temperature Range: -55℃~+125℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Materials
1 Inner Conductor 0.59 SPC
2 Dielectric 1.68 PTFE
3 Outer Conductor 2.18 Immersion Tin Copper / Cu-Sn-Zn Alloy

Mechanical & Environmental Specifications

Static Bend Radius: 7mm

Weight: 0.021Kg/m

Installation & Operating Temperature Range: -55℃~+125℃

Electrical Specifications

Frequency Range: 40GTLZ

Cutoff Frequency: 68GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 81%

Shielding Effectiveness: >165dB

Voltage Power: 500V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000 26500 40000
Attenuation (dB/100m) 58.3 82.8 101.7 144.9 168.0 188.4 210.6 255.5 312.8 388.7
Avg. Power (kW) 0.259 0.182 0.148 0.104 0.090 0.080 0.072 0.059 0.048 0.039
K1= 1.825328
K2= 0.000590
Calculation= K1* √FMhz+K2*FMHz

Features & Advantages

Low Loss

Low VSWR

Low Passive Intermodulation (-155dbc)

Typical Applications

RF Module Internal Interconnection

Precision Instruments Internal Interconnection

Small, Complex Installation Space