Cable Construction Specifications
| Description | Dimensions (mm) | Materials | |
| 1 | Inner Conductor | 0.59 | SPC |
| 2 | Dielectric | 1.68 | PTFE |
| 3 | Outer Conductor | 2.18 | Immersion Tin Copper / Cu-Sn-Zn Alloy |
Mechanical & Environmental Specifications
Static Bend Radius: 7mm
Weight: 0.021Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 40GTLZ
Cutoff Frequency: 68GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 81%
Shielding Effectiveness: >165dB
Voltage Power: 500V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
| Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 |
| Attenuation (dB/100m) | 58.3 | 82.8 | 101.7 | 144.9 | 168.0 | 188.4 | 210.6 | 255.5 | 312.8 | 388.7 |
| Avg. Power (kW) | 0.259 | 0.182 | 0.148 | 0.104 | 0.090 | 0.080 | 0.072 | 0.059 | 0.048 | 0.039 |
| K1= | 1.825328 | |||||||||
| K2= | 0.000590 | |||||||||
| Calculation= | K1* √FMhz+K2*FMHz | |||||||||
Features & Advantages
Low Loss
Low VSWR
Low Passive Intermodulation (-155dbc)
Typical Applications
RF Module Internal Interconnection
Precision Instruments Internal Interconnection
Small, Complex Installation Space