Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 1.05 | SPC |
2 | Dielectric | 3.00 | PTFE |
3 | Outer Conductor | 3.58 | Immersion Tin Copper / Cu-Sn-Zn Alloy |
Mechanical & Environmental Specifications
Static Bend Radius: 13.5mm
Weight: 0.045Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 26.5GTLZ
Cutoff Frequency: 38GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 81%
Shielding Effectiveness: >165dB
Voltage Power: 1000V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Attenuation (dB/100m) | 30.8 | 43.9 | 54.9 | 77.1 | 89.5 | 100.5 | 112.5 | 136.9 | 168.1 |
Avg. Power (kW) | 0.584 | 0.411 | 0.334 | 0.234 | 0.201 | 0.179 | 0.160 | 0.132 | 0.107 |
K1= | 0.961145 | ||||||||
K2= | 0.000440 | ||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Low Passive Intermodulation (-155dbc)
Typical Applications
RF Module Internal Interconnection
Precision Instruments Internal Interconnection
Small, Complex Installation Space