Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 0.91 | Stranded SPC |
2 | Dielectric | 2.65 | LD-PTFE |
3 | Outer Conductor | 2.78 | Aluminum Foil |
4 | Outer Shield | 3.15 | SPC Braid |
5 | Jacket | 4.00 | Black FEP |
Mechanical & Environmental Specifications
Static Bend Radius: 18mm
Dynamic Bend Radius: 36mm
Weight: 0.029Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 18GTLZ
Cutoff Frequency: 40GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 76%
Shielding Effectiveness: >70dB
Voltage Power: 1000V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 |
Attenuation (dB/100m) | 44.7 | 63.6 | 78.2 | 111.7 | 129.6 | 145.5 | 162.8 | 198.0 |
Avg. Power (kW) | 0.353 | 0.248 | 0.202 | 0.141 | 0.122 | 0.108 | 0.097 | 0.080 |
K1= | 1.395308 | |||||||
K2= | 0.000600 | |||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Cost-effective
Typical Applications
Cabinet Internal Interconnection
Wireless Telecommunication Base Station Interconnection