Cable Construction Specifications
| Description | Dimensions (mm) | Materials | |
| 1 | Inner Conductor | 2.30 | Solid SPC |
| 2 | Dielectric | 6.80 | LD-PTFE |
| 3 | Outer Conductor | 6.95 | Aluminum Foil |
| 4 | Outer Shield | 7.50 | SPC Braid |
| 5 | Jacket | 8.10 | Blue FEP |
Mechanical & Environmental Specifications
Static Bend Radius: 40mm
Dynamic Bend Radius: 81mm
Weight: 0.134Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Electrical Specifications
Frequency Range: 18GTLZ
Cutoff Frequency: 19GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 76%
Shielding Effectiveness: >90dB
Voltage Power: 2000V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
| Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 16000 | 18000 |
| Attenuation (dB/100m) | 15.1 | 21.8 | 27.2 | 40.1 | 47.3 | 53.8 | 61.0 | 71.0 | 76.3 |
| Avg. Power (kW) | 1.471 | 1.015 | 0.814 | 0.553 | 0.469 | 0.412 | 0.363 | 0.312 | 0.291 |
| K1= | 0.448000 | ||||||||
| K2= | 0.000898 | ||||||||
| Calculation= | K1* √FMhz+K2*FMHz | ||||||||
Features & Advantages
Low Loss
Low VSWR
Cost-effective
Typical Applications
Cabinet Internal Interconnection
Wireless Telecommunication Base Station Interconnection