Used Error Analyzer Agilent 86130A

Complementing the 86100A Infiniium DCA, the 86130A brings a new level of insight into your testing toolbox. Powerful analysis, easy setting and use, together in a small, expandable package makes digital testing easy.

Our contacts:

Phone: 7183408296
Email: info@raelsys.com

The Agilent 86130A BitAlyzer is a combination of Pattern Generator and Error Detector and is designed to quickly solve design and manufacturing problems. Complementing the 86100A Infiniium DCA, the 86130A brings a new level of insight into your testing toolbox. Powerful analysis, easy setting and use, together in a small, expandable package makes digital testing easy.

Other features and specifications of:

●Pattern Generator Specs:

oOperating Frequency: 50 MHz to 3.6 GHz

o50 Mb/s to 3.6 Gb/s with external clock

o50 Mb/s to 3.0 Gb/s with internal clock source

oFrequency Accuracy: ±20 ppm

oExcellent waveform performance

oEasy setup

oTest Patterns:

■2N-1 PRBS

■231-1, 223-1, 215-1, 210-1, 27-1

■2N PRBS

■223, 215, 210, 27

■Variable Mark Density

■1/8, 1/4, 1/2, 3/4, 7/8

■User Defined Patterns

■Variable length patterns from 1 to 8 Mbits

■Alternating Patterns

■Change between two equal length user patterns, each up to 4 Mbits long. Changeover is synchronous with the end of a pattern, under the control of the front panel or the Auxiliary Input.

■Error Add

■Single, continuously variable between 1×10-2 and 1×10-9, and user specified bursts of errors.

■Pattern Editor

■Fully flexible pattern editor included with “cut”, “copy” and “paste” functions.

●Error Detector Specs:

oOperating Frequency: 50 MHz to 3.6 GHz

oTest Paterns: As specified for Pattern Generator

oAuto-Align

■Includes synchronizing, data polarity, clock/ data align, clock invert, 0/1 threshold center.

oData In Delay

■Manual Data In Delay/Auto Clock-Data Align

oThreshold Setting

■Manual set, Average DC level set, Auto 0/1 center

oSynchronization

■Manual, Automatic, Burst*, Capture*. Sync threshold adjustable from 10-1 to 10-9.

oResults

■Accumulated measurements may be run once, repetitively or manual start/ stop. Delta (instantaneous) BER always available.

●Manual start/ stop

oTime: Accumulate for periods from 1second to 100 days

oErrors: Until at least 10/100/1000 errors

oBits: 107 to 1015 bits

●Result Displays

oDelta BER Results

■Delta Error Ratio, Delta Error Count, Graph of BER vs Time

oAccumulated Results

■Bit Count, Error Ratio, Error Count, Errored One Count, Errored Zero Count, Error Free Seconds, Errored Seconds, Elapsed Accumulation Time, Sync Loss Seconds, Power Loss Seconds, Graph vs Time

oEye Results

■Eye Width, Eye Height, Eye Voltage Center value, Eye Time Center value, Delta Error Ratio at Eye Center on completion of Autoalign

oSYNTHESYS Error Analysis:

■Graphs of Burst Lengths, Error Free Intervals, Correlation Analysis, Pattern Sensitivity Analysis, Block Analysis, Strip Chart