Used Oscilloscope Tektronix DPO3054

The large, high-resolution display shows intricate signal details. Dedicated front-panel controls simplify operation. A USB host on the front panel allows you to easily transfer screenshots, instrument settings, and waveform data to a memory stick.

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

The Tektronix DPO3054 Digital Phosphor Oscilloscope provides the feature-rich tools you need to simplify and speed debug of your complex design. The large, high-resolution display shows intricate signal details. Dedicated front-panel controls simplify operation. A USB host on the front panel allows you to easily transfer screenshots, instrument settings, and waveform data to a memory stick.

Features and Specifications of:

●Features:

oEase of Use Features:

■Wave Inspector® Controls Provide Easy Navigation and Automated Search of Waveform Data

■29 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis

■TekVPI® Probe Interface Supports Active, Differential, and Current Probes for Automatic Scaling and Units

■9 in. (229 mm) WVGA Widescreen Color Display

■Compact, Portable, Small Footprint and Lightweight – Only 5.8 in. (147 mm) deep and 9 lb. (4 kg)

oConnectivity:

■USB 2.0 Host Port on both the Front Panel and Rear Panel for Quick and Easy Data Storage, Printing, and Connecting a USB Keyboard

■USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge®-compatible Printer

■Integrated 10/100 Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector

oOptional Serial Triggering and Analysis:

■Automated Serial Triggering, Decode, and Search Options for I2C, SPI, CAN, LIN, RS-232/422/485/UART, and I2S/LJ/RJ/TDM

oOptional Application Support:

■Power Analysis

■HDTV and Custom Video Analysis

●Specifications:

oCharacteristics:

■Input Channels:  4

■Analog Bandwidth (-3 dB):  500 MHz

■Calculated Rise Time 5 mV/div (typical):  700 ps

■Hardware Bandwidth Limits:  20 MHz, 150 MHz

■Input Coupling:  AC, DC, GND

■Input Impedance:  1 MO ±1%, 75 O ±1%, 50 O ±1%

■Input Sensitivity Range, 1 MO:  1 mV/div to 10 V/div

■Input Sensitivity Range, 75 O, 50 O:  1 mV/div to 1 V/div

■Vertical Resolution:  8 bits (11 bits with Hi Res

■Maximum Input Voltage, 1 MO:  300 VRMS with peaks = ±450 V

■Maximum Input Voltage, 75 O, 50 O:  5 VRMS with peaks = ±20 V

■ DC Gain Accuracy:

■±1.5% for 5 mV/div and above

■±2.0% for 2 mV/div

■±2.5% for 1 mV/div

■Channel-to-Channel Isolation (Any 2 Channels at Equal Vertical Scale):

■=100:1 at =100 MHz

■=30:1 at >100 MHz up to the rated BW

oHorizontal System Analog Channels:

■Max Sample Rate:  2.5 GS/s

■Max Record Length:  5 Mpoints

■Max Duration of Time Captured at Highest Sample Rate:  2 ms

■Time-base Range (s/div):  1 ns to 1000 s

■Time-base Delay Time Range:  -10 divisions to 5000 s

■Channel-to-Channel Deskew Range:  ±100 ns

oTrigger System:

■Main Trigger Modes:  Auto, Normal, and Single

■Trigger Coupling:

■DC, AC, HF reject (attenuates >50 kHz)

■LF reject (attenuates

■Noise reject (reduces sensitivity)

■Trigger Holdoff Range:  20 ns to 8 s

oTrigger Sensitivity:

■Internal DC Coupled:  0.5 div from DC to 50 MHz, increasing to 1 div at rated bandwidth

■External (Auxiliary Input):  200 mV from DC to 50 MHz increasing to 500 mV at 250 MHz

o Trigger Level Range:

■Any Channel:  ±8 divisions from center of screen

■External (Auxiliary Input):  ±8 V