The Tektonix DPO7054 Oscilloscope is a real-time digital phosphor oscilloscope and is the industry’s best solution to the challenging signal integrity issues faced by designers verifying, characterizing, debugging, and testing sophisticated electronic designs.
The Tektronix DPO7054 Oscilloscope features exceptional performance in signal acquisition and analysis, operational simplicity, and unmatched debugging tools to accelerate your day-to-day tasks. It has the largest screen in the industry and its intuitive user interface provides easy access to the maximum amount of information.
Features and Specifications of:
Features and Benefits:
●500 MHz Bandwidth Model for Serial and Digital Applications
●Up to 40 GS/s Real-time Sample Rate on One Channel and up to 10 GS/s on All Four Channels
●Up to 500 Megasamples Record Length with MultiView Zoom™ Feature for Quick Navigation
●>250,000 wfms/s Maximum Waveform Capture Rate
●Up to 310,000 Waveforms per Second with FastFrame™ Segmented Memory Acquisition Mode
●User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy
●MyScope® Custom Windows and Right Mouse Click Menus for Exceptional Efficiency
●Event Search and Mark to Find Specific Events in the Entire Waveform
●Pinpoint® Triggering provides the Most Flexible and Highest Performance Triggering, with Over 1400 Combinations to Address Virtually Any Triggering Situation.
●12.1” XGA Display with Touch Screen
●Communications Mask Testing
●Clock Recovery from Serial Data Streams
●64-bit NRZ Serial Pattern Trigger for Isolation of Pattern-dependent Effects up to 1.25 Gb/s
●Low-speed Serial Protocol Triggering and Decode (I2C, SPI, RS-232, CAN, LIN, and FlexRay)
●Technology-specific Software Solutions provide Built-in Domain Expertise for MIPI® D-PHY, Ethernet, USB 2.0 Compliance Testing, Jitter, Timing, Eye Diagram, Power, DDR Memory Bus Analysis, CAN, LIN, and FlexRay Network Design
●OpenChoice® Software with Microsoft Windows XP OS enables Built-in Networking and Extended Analysis
Applications:
●Signal Integrity, Jitter, and Timing Analysis
●Verification, Debug, and Characterization of Sophisticated Designs
●Debugging and Compliance Testing of Serial Data Streams for Telecom and Datacom Industry Standards
●Low-speed Serial Bus Design (I2C, SPI, RS-232, CAN, LIN, and FlexRay)
●Investigation of Transient Phenomena
●Power Measurements and Analysis
●Spectral Analysis
Characteristics:
●Vertical System:
oInput Channels: 4
oBandwidth (DSP Bandwidth Enhance): 500 MHz
oRise Time (DSP Bandwidth Enhance): 460 ps
oHardware Analog Bandwidth (-3 dB): 500 MHz
oRise Time 10% to 90% (Typical): 460 ps
oRise Time 20% to 80% (Typical): 310 ps
oDC Gain Accuracy: ±1% with offset/position set to 0
oInput Coupling: AC, DC, GND
oInput Impedance (Software selectable):
■1 MO ±1% with 13 pF ±2 pF or
■50 O ±1%
oInput Sensitivity:
■1 MO: 1 mV/div to 10 V/div
■50 O: 1 mV/div to 1 V/div
oVertical Resolution: 8 bit (>11 bit with Hi Res)
oMax Input Voltage:
■1 MO: ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz
■50 O: 5 VRMS with peaks less than ±24 V
oPosition Range: ±5 divisions
oOffset Range:
■1 mV/div to 50 mV/div: ±1 V
■50.5 mV/div to 99.5 mV/div: ±(1.5 V – 10 divisions)
■100 mV/div to 500 mV/div: ±10 V
■505 mV/div to 995 mV/div: ±(15 V – 10 divisions)
■1 V/div to 5 V/div: ±100
■5.05 V/div to 10 V/div: ±(150 V – 10 divisions)
oOffset Accuracy:
■1 mV/div to 9.95 mV/div: ±0.2% (offset value-position) ±0.1 div ±1.5 mV
■10 mV/div to 99.5 mV/div: ±0.35% (offset value-position) ±0.1 div ±1.5 mV
■100 mV/div to 1 V/div: ±0.35% (offset value-position) ±0.1 div ±15 mV
■1.01 V/div to 10 V/div: ±0.25% (offset value-position) ±0.1 div ±150 mV
oDelay Between Any Two Channels (Typical): =100 ps (50 O, DC coupling and equal V/div at or above 10 mV/div)
oChannel-to-Channel Isolation (Any 2 channels at equal Vertical Scale Settings) (Typical):
■=100:1 at =100 MHz
■=30:1 between 100 MHz and 2.5 GHz
■> 20:1 between 2.5 and 3.5 GHz
●Time Base System:
oTime Base Range: 50 ps/div to 1000 s/div
oTime Resolution (in ET/IT mode): 500 fs
oTime Base Delay Time Range: 5 ns to 250 s
oChannel-to-Channel Deskew: Range ±75 ns
oDelta Time Measurement Accuracy: ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS
oTrigger Jitter (RMS):
■1.5 psRMS (typical) with enhanced triggering OFF
oJitter Noise Floor:
oTime Base Accuracy: ±2.5 ppm + Aging
●Acquisition System:
oReal-Time Sample Rates:
■1 Channel (Max): 20 GS/s
■2 Channels (Max): 10 GS/s
■3-4 Channels (Max): 5 GS/s
■Equivalent Time Sample Rate (Max): 4 TS/s (for repetitive signals)
oMaximum Record Length Per Channel:
■Standard Configuration:
■1 Channel: 50 M
■2 Channel: 25 M
■4 Channel: 12.5 M
■Record Length Opt. 2RL:
■1 Channel: 125 M
■2 Channel: 50 M
■4 Channel: 25 M
■Record Length Opt. 5RL
■1 Channel: 250 M
■2 Channel: 125 M
■4 Channel: 50 M
●Maximum Duration at Highest Real-Time Resolution (1 Channel):
oResolution: 50 ps (20 GS/s)
oMax Duration with Standard Record Length and Sample Rate: 2 ms
oMax Duration with Opt 2RL: 4 ms
oMax Duration with Opt 5RL: 10 ms




