When the Keysight 81130A (Agilent) Pulse Data Generator Mainframe is combined with one or two Keysight 81131A (Agilent) output modules it becomes a 400 MHz precision single / dual-channel Pulse Data Generator. When the Agilent 81130A Mainframe is combined with one or two Keysight 81132A (Agilent) output modules it becomes a precision 600 MHz/1.32 Gbps single / dual-channel Pulse Date Generator. (Keysight 81131A and 81132A output channels can not be combined together into the very same Keysight 81130A (Agilent) Mainframe.)
In order to meet the highly complex stimuli requirement of today’s devices, the Keysight 81130A (Agilent) can sequence and loop its memory for very deep patterns. Digital channel addition allows the generation of signals with two different pulse widths and delays or of data rates up to 1.32 Gbit/s in one single channel. The Keysight 81130A (Agilent) Pulse Data Generator is perfectly suited to operate in the 170 kHZ to 400 / 660 MHz frequency range, but is capable of operation in the extended range down to 1 kHz.
Features and Specifications of :
●Features:
oProduces all the standard pulses and digital patterns needed to test current logic technologies
oPulse, burst, pattern modes selectable
oPrecision timing model and sequenced PRBS capability
oEXOR channel addition
oSMA(f) 3.5 mm: Differential
oPLL oscillator (not triggerable) provides advanced delay and superb width accuracy
oLarge segmentable 64 kbit memory
oCounted loop
oFlexibility for serial data requirements such as data communication messages and initialization routines
oFour combined independent timing eyes which allow pulses with almost arbitrary shapes in a single signal
oFlexible pulses or patterns for Digital Designs:
■Pattern mode from 80 MHz to 660 MHz, including pseudo-random binary sequence
■The outputs of dual-channel instruments can be added
■Upward compatibility
■Individual solutions for frequencies up to 50, 80, 165, 330, 400 and 660 MHz
■100% from / fit compatibility
oClean, accurate pulses with excellent repeatability providing reliable measurements
oFeatures such as the clear graphical display, autoset, help, store / recall, preset TTL / ECL levels, selectable units (such as current / voltage, width / duty-cycle), and load compensation ensure a high level of convenience that make it easy to use
●Specifications:
oMainframe: 81130A
oChannel Models:
■81131A
■81132A
oNumber of Channels:
■81131A: 1 or 2
■81132A: 1 or 2
oFrequency Range:
■81131A: 1 kHz – 400 MHz
■81132A: 1 kHz – 660 MHz
oVariable delay range:
■81131A: 2.5 ns – 1 ms
■81132A: 1.5 ns – 1 ms
oPeriod RMS – jitter:
■81131A: 0.00 ns to 3.00 μs
■81132A: 0.00 ns to 3.00 μs
oWidth Range:
■81131A: 1.25 ns – (period – 1.25 ns)
■81132A: 750 ps – (period – 750 ps)
oAmplitude Range:
■81131A: 100 mV to 3.8 V
■81132A: 100 mV to 2.5 V
oTransition Time Range (10 / 90):
■81131A: 800 ps or 1.6 ns – selectable
■81132A: 500 ps typical – fixed
oSource Impedance:
■81131A: 50 Ω
■81132A: 50 Ω