Agilent MSOX4052A

Oscilloscope, 500 MHz, 2 + 16 Chs.

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

The Keysight MSOX4052A is a two-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The MSOX4052A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.

Features and Specifications of the Keysight MSOX4052A (Agilent) Oscilloscope include:

Features of the Agilent MSOX4052A include:

  • One million waveforms per second update rate

  • MegaZoom IV smart memory technology

  • Standard segmented memory

  • Large 12.1-inch capacitive touch display

  • Interface designed for touch

  • Innovative InfiniiScan Zone touch triggering

  • 5 instruments in 1, with full upgradability, including bandwidth:

    • Oscilloscope  

    • Logic analyzer (MSO) 

    • Serial protocol analyzer, including USB (optional)

    • WaveGen 20 MHz dual channel arbitrary/function generator (optional)

    • Digital voltmeter (DVM) option:

      • with 3-digit voltage

      • with 5-digit frequency counter measurements

Specifications of the Keysight MSOX4052A include:

  • Bandwidth (-3 dB):  500 MHz

  • All-channel real-time bandwidth:  500 MHz

  • Calculated rise time (10 – 90%):  ≤ 700 ps

  • Input channels:  

    • 2 analog

    • 16 digital

  • Maximum sample rate:

    • 5 GSa/s half channel

    • 2.5 GSa/s all channel

  • Maximum memory depth:  Standard 4 Mpts, standard segmented memory

  • Display size and type:  12.1-inch high-definition capacitive touch display

  • Waveform update rate:  > 1 million waveforms per second

  • System bandwidth with N2894A standard passive probe: 500 MHz

  • Vertical system analog channels:

    • Hardware bandwidth limits:  Approximately 20 MHz (selectable)

    • Input coupling:  AC, DC

    • Input impedance:  Selectable:  

      • 1 MΩ ± 1% (16 pF)

      • 50 Ω ± 1.5%

    • Input sensitivity range:  1mV/div to 5 V/div (1 MΩ and 50 Ω)

    • Vertical resolution:  8 bits (measurement resolution is 12 bits with averaging)

    • Maximum input voltage:

      • 300 Vrms, 400 Vpk

      • Transient overvoltage 1.6 kVpk

      • With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms

      • Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk

    • DC vertical gain accuracy: ± 2.0% full scale

    • DC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting

    • Channel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model

    • Offset range:

      • ± 5 V (< 10 mV/div)

      • ± 20 V (10 to 200 mV/div)

      • ± 75 V (> 200 mV/div)

  • Vertical system digital channels:

    • Digital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)

    • Thresholds: Threshold per pod

    • Threshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)

    • User-defined threshold range:  ± 8.0 V in 10 mV steps

    • Maximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk

    • Threshold accuracy:  ± (100 mV + 3% of threshold setting)

    • Maximum input dynamic range:  ± 10 V about threshold

    • Minimum voltage swing:  500 mVpp

    • Input impedance:  100 kΩ ± 2% at probe tip

    • Input capacitance:  ~8 pF

    • Vertical resolution: 1 bit

  • Horizontal system analog channels:  

    • Time base range:  2 ns/div to 50 s/div

    • Time base accuracy:  ± 10 ppm

    • Time base delay time range:

      • Pre-trigger:  Greater of 1 screen width or 200 μs (400 μs in interleaving mode)

      • Post-trigger: 1 s to 500 s

    • Channel-to-channel deskew range:  ± 100 ns

    • Δ Time accuracy (using cursors):  ± 0.001% of reading ± 0.16% screen width ± 30pS

    • Modes:  Main, zoom, roll, XY

    • XY:

      • On channels 1 and 2 only

      • Z Blanking on ext trigger input, 1.4 V threshold  

      • Bandwidth:  Maximum bandwidth

      • Phase error at 1 MHz: < 0.5 degree

      • Time base: 200 ns/div to 50 ms/div

  • Horizontal system digital channels:  

    • Minimum detectable pulse width:  2 ns

    • Channel-to-channel skew:

      • 2 ns (typical)

      • 3 ns (maximum)

  • Aquisition system:

    • Maximum analog channels sample rate:  

      • 5 GSa/s half channel interleaved

      • 2.5 GSa/s all channel

    • Maximum analog channels record length:

      • 4 Mpts half channel interleaved

      • 2 Mpts all channel

    • Maximum digital channels sample rate:  1.25 GSa/s

    • Maximum digital channels record length:  2 Mpts (with digital channels only)

    • Modes:

      • Normal:  Default mode

      • Peak detect:  Capture glitches as narrow as 200 ps at all time base settings

      • Averaging:  Selectable from 2, 4, 8, 16, 64, … to 65,536

      • High resolution:

        • Real time boxcar averaging reduces random noise and effectively increases vertical resolution

        • 12 bits:  ≥ 50 μs/div

        • 11 bits:  ≥ 20 μs/div

        • 10 bits:  ≥ 10 μs/div

        • 9 bits:  ≥ 5 μs/div

      • Segmented:

        • Segmented memory optimizes available memory for data streams that have long dead times between activity

        • Maximum segments = 1000

        • Re-arm time = 1 μs (minimum time between trigger events)

        • Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)

      • Roll:  

        • Displays the waveform moving across the screen from right to left

        • Available at the time base 50 ms/div or slower

  • Trigger system:

    • Trigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)

    • Trigger modes:

      • Normal: Requires trigger event for scope to trigger

      • Auto : Triggers automatically in absence of trigger event

      • Single:

        • Front panel button that triggers only once on a trigger event

        • Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode

      • Force:  Front panel button that forces a trigger

    • Trigger coupling:  

      • DC: DC coupled trigger

      • AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)

      • High frequency reject:  Cutoff frequency ~ 50 kHz

      • Low frequency reject:  Cutoff frequency ~ 50 kHz 

      • Noise reject:

        • Adds hysteresis to the trigger circuitry

        • Selectable OFF or ON

        • Decreases sensitivity 2x

    • Trigger holdoff range: 40 ns to 10.00 s  

    • Trigger sensitivity:

      • Internal:

        • < 10 mV/div: greater of 1 div or 5 mV

        • ≥ 10 mV/div: 0.6 div

      • External:

        • ± 1.6 V:  

          • 40 mVpp DC to 100 MHz

          • 70 mVpp 100 MHz to 200 MHz

        • ± 8 V:  

          • 200 mVpp DC to 100 MHz

          • 350 mVpp 100 MHz to 200 MHz

    • Trigger level range:

      • Any channel:  ± 6 div from center screen

      • External:  

        • ± 8 V range = ± 8 V

        • ± 1.6 V range = ± 1.6 V

  • Connectivity:

    • USB 2.0 hi-speed host port:

      • x3 ports, 2 front and one rear panel

      • Supports memory devices, printers, keybords and mice

    • USB 2.0 hi-speed device port:

      • One port on rear panel

      • USB Test & Measurement Class (USBTMC) compatible

    • LAN port:

      • 10/100Base-T port on rear panel

      • LXI IPv6 extended function

    • Web remote control:  VNC Web interface (via major Web browsers)

    • Video out port:  

      • SVGA out on rear panel

      • Connect oscilloscope display to an external monitor or projector

    • GPIB port:  N4865A GPIB-to-LAN adapter (optional)

    • 10 MHz out/in:  

      • BNC connector on the rear panel

      • Suported modes:  Off, 10 MHz out, or reference signal mode (10 MHz in)

    • Trigger out:  

      • BNC connecter on the rear panel 

      • Supported modes:  triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse