The Keysight MSOX4052A is a two-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The MSOX4052A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.
Features and Specifications of the Keysight MSOX4052A (Agilent) Oscilloscope include:
Features of the Agilent MSOX4052A include:
-
One million waveforms per second update rate
-
MegaZoom IV smart memory technology
-
Standard segmented memory
-
Large 12.1-inch capacitive touch display
-
Interface designed for touch
-
Innovative InfiniiScan Zone touch triggering
-
5 instruments in 1, with full upgradability, including bandwidth:
-
Oscilloscope
-
Logic analyzer (MSO)
-
Serial protocol analyzer, including USB (optional)
-
WaveGen 20 MHz dual channel arbitrary/function generator (optional)
-
Digital voltmeter (DVM) option:
-
with 3-digit voltage
-
with 5-digit frequency counter measurements
Specifications of the Keysight MSOX4052A include:
-
Bandwidth (-3 dB): 500 MHz
-
All-channel real-time bandwidth: 500 MHz
-
Calculated rise time (10 – 90%): ≤ 700 ps
-
Input channels:
-
2 analog
-
16 digital
-
Maximum sample rate:
-
5 GSa/s half channel
-
2.5 GSa/s all channel
-
Maximum memory depth: Standard 4 Mpts, standard segmented memory
-
Display size and type: 12.1-inch high-definition capacitive touch display
-
Waveform update rate: > 1 million waveforms per second
-
System bandwidth with N2894A standard passive probe: 500 MHz
-
Vertical system analog channels:
-
Hardware bandwidth limits: Approximately 20 MHz (selectable)
-
Input coupling: AC, DC
-
Input impedance: Selectable:
-
1 MΩ ± 1% (16 pF)
-
50 Ω ± 1.5%
-
Input sensitivity range: 1mV/div to 5 V/div (1 MΩ and 50 Ω)
-
Vertical resolution: 8 bits (measurement resolution is 12 bits with averaging)
-
Maximum input voltage:
-
300 Vrms, 400 Vpk
-
Transient overvoltage 1.6 kVpk
-
With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
-
Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
-
DC vertical gain accuracy: ± 2.0% full scale
-
DC vertical offset accuracy: ± 0.1 div ± 2 mV ± 1% of offset setting
-
Channel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model
-
Offset range:
-
± 5 V (< 10 mV/div)
-
± 20 V (10 to 200 mV/div)
-
± 75 V (> 200 mV/div)
-
Vertical system digital channels:
-
Digital input channels: 16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
-
Thresholds: Threshold per pod
-
Threshold selections: TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
-
User-defined threshold range: ± 8.0 V in 10 mV steps
-
Maximum input voltage: ± 40 V peak CAT l; transient overvoltage 800 Vpk
-
Threshold accuracy: ± (100 mV + 3% of threshold setting)
-
Maximum input dynamic range: ± 10 V about threshold
-
Minimum voltage swing: 500 mVpp
-
Input impedance: 100 kΩ ± 2% at probe tip
-
Input capacitance: ~8 pF
-
Vertical resolution: 1 bit
-
Horizontal system analog channels:
-
Time base range: 2 ns/div to 50 s/div
-
Time base accuracy: ± 10 ppm
-
Time base delay time range:
-
Pre-trigger: Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
-
Post-trigger: 1 s to 500 s
-
Channel-to-channel deskew range: ± 100 ns
-
Δ Time accuracy (using cursors): ± 0.001% of reading ± 0.16% screen width ± 30pS
-
Modes: Main, zoom, roll, XY
-
XY:
-
On channels 1 and 2 only
-
Z Blanking on ext trigger input, 1.4 V threshold
-
Bandwidth: Maximum bandwidth
-
Phase error at 1 MHz: < 0.5 degree
-
Time base: 200 ns/div to 50 ms/div
-
Horizontal system digital channels:
-
Minimum detectable pulse width: 2 ns
-
Channel-to-channel skew:
-
2 ns (typical)
-
3 ns (maximum)
-
Aquisition system:
-
Maximum analog channels sample rate:
-
5 GSa/s half channel interleaved
-
2.5 GSa/s all channel
-
Maximum analog channels record length:
-
4 Mpts half channel interleaved
-
2 Mpts all channel
-
Maximum digital channels sample rate: 1.25 GSa/s
-
Maximum digital channels record length: 2 Mpts (with digital channels only)
-
Modes:
-
Normal: Default mode
-
Peak detect: Capture glitches as narrow as 200 ps at all time base settings
-
Averaging: Selectable from 2, 4, 8, 16, 64, … to 65,536
-
High resolution:
-
Real time boxcar averaging reduces random noise and effectively increases vertical resolution
-
12 bits: ≥ 50 μs/div
-
11 bits: ≥ 20 μs/div
-
10 bits: ≥ 10 μs/div
-
9 bits: ≥ 5 μs/div
-
Segmented:
-
Segmented memory optimizes available memory for data streams that have long dead times between activity
-
Maximum segments = 1000
-
Re-arm time = 1 μs (minimum time between trigger events)
-
Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)
-
Roll:
-
Displays the waveform moving across the screen from right to left
-
Available at the time base 50 ms/div or slower
-
Trigger system:
-
Trigger sources: Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
-
Trigger modes:
-
Normal: Requires trigger event for scope to trigger
-
Auto : Triggers automatically in absence of trigger event
-
Single:
-
Front panel button that triggers only once on a trigger event
-
Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode
-
Force: Front panel button that forces a trigger
-
Trigger coupling:
-
DC: DC coupled trigger
-
AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)
-
High frequency reject: Cutoff frequency ~ 50 kHz
-
Low frequency reject: Cutoff frequency ~ 50 kHz
-
Noise reject:
-
Adds hysteresis to the trigger circuitry
-
Selectable OFF or ON
-
Decreases sensitivity 2x
-
Trigger holdoff range: 40 ns to 10.00 s
-
Trigger sensitivity:
-
Internal:
-
< 10 mV/div: greater of 1 div or 5 mV
-
≥ 10 mV/div: 0.6 div
-
External:
-
± 1.6 V:
-
40 mVpp DC to 100 MHz
-
70 mVpp 100 MHz to 200 MHz
-
± 8 V:
-
200 mVpp DC to 100 MHz
-
350 mVpp 100 MHz to 200 MHz
-
Trigger level range:
-
Any channel: ± 6 div from center screen
-
External:
-
± 8 V range = ± 8 V
-
± 1.6 V range = ± 1.6 V
-
Connectivity:
-
USB 2.0 hi-speed host port:
-
x3 ports, 2 front and one rear panel
-
Supports memory devices, printers, keybords and mice
-
USB 2.0 hi-speed device port:
-
One port on rear panel
-
USB Test & Measurement Class (USBTMC) compatible
-
LAN port:
-
10/100Base-T port on rear panel
-
LXI IPv6 extended function
-
Web remote control: VNC Web interface (via major Web browsers)
-
Video out port:
-
SVGA out on rear panel
-
Connect oscilloscope display to an external monitor or projector
-
GPIB port: N4865A GPIB-to-LAN adapter (optional)
-
10 MHz out/in:
-
BNC connector on the rear panel
-
Suported modes: Off, 10 MHz out, or reference signal mode (10 MHz in)
-
Trigger out:
-
BNC connecter on the rear panel
-
Supported modes: triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse