Cable Construction Specifications
| Description | Dimensions (mm) | Material | |
| 1-6 | TLC220 Cable | 5.10 | FEP |
| 7-8 | Protect Layer | 6.70 | SPC |
| 9-10 | Jacket | 7.60 | PTFE |
Mechanical & Environmental Specifications
Frequency Range: DC-26.5GTLZ
VSWR: ≤1.25@26.5GTLZ
Repeated bending: 600,000 times
Temperature Range: -55℃~+125℃
Electrical Specifications
Static Bend Radius: 50mm
Dynamic Bend Radius: 80mm
Mechanical Phase: ±5°
Amplitude Stability: ±0.05dB
Weight: 0.135Kg/m
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
| Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 |
| Attenuation (dB/100m) | 27.1 | 38.9 | 48.1 | 69.6 | 81.3 | 91.9 | 103.5 | 127.4 | 158.8 |
| Avg. Power (kW) | 0.821 | 0.573 | 0.463 | 0.320 | 0.274 | 0.242 | 0.215 | 0.175 | 0.140 |
| K1= | 0.828800 | ||||||||
| K2= | 0.000900 | ||||||||
| Calculation= | K1* √FMhz+K2*FMHz | ||||||||
Features & Advantages
Low Loss
Low VSWR
Bending, Shake, Torsion & Pull resistance
Typical Applications
Laboratory Test
Anechoic Chambers
System Test
High-Precision Instruments Test
On-site Testing and Measurement