TLC500

Static Bend Radius: 25mm
Dynamic Bend Radius: 50mm
Weight: 0.055Kg/m
Installation & Operating Temperature Range: -55℃~+165℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Material
1 Inner Conductor 1.44 Stranded SPC
2 Dielectric 3.85 LD-PTFE
3 Inner Shield 4.05 SPC Strip
4 Interlayer 4.30 LD-PTFE
5 Outer Shield 4.65 SPC Braid
6 Jacket 5.10 Blue FEP

Mechanical & Environmental Specifications

Static Bend Radius: 25mm

Dynamic Bend Radius: 50mm

Weight: 0.055Kg/m

Installation & Operating Temperature Range: -55℃~+165℃

Electrical Specifications

Frequency Range: 26.5GTLZ

Cutoff Frequency: 29GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 82%

Shielding Effectiveness: >90dB

Voltage Power: 2000V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000 26500
Attenuation (dB/100m) 27.1 38.9 48.1 69.6 81.3 91.9 103.5 127.4 158.8
Avg.Power (kW) 0.821 0.573 0.463 0.320 0.274 0.242 0.215 0.175 0.140
K1= 0.828800
K2= 0.000900
Calculation = K1* √FMhz+K2*FMHz

Features & Advantages

Low Loss

Low VSWR

Bending, Shake, Torsion & Pull Resistance

Typical Applications

Aviation Electronics

Electronic Confrontation

Laboratory Test

RF Microwaves Device Test