TLC400

Static Bend Radius: 21mm
Dynamic Bend Radius: 42mm
Weight: 0.040Kg/m
Installation & Operating Temperature Range: -55℃~+165℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Material
1 Inner Conductor 1.02 Solid SPC
2 Dielectric 2.80 LD-PTFE
3 Inner Shield 2.95 SPC Strip
4 Interlayer 3.20 LD-PTFE
5 Outer Shield 3.62 SPC Braid
6 Jacket 4.20 Blue FEP

Mechanical & Environmental Specifications

Static Bend Radius: 21mm

Dynamic Bend Radius: 42mm

Weight: 0.040Kg/m

Installation & Operating Temperature Range: -55℃~+165℃

Electrical Specifications

Frequency Range: 40GTLZ

Cutoff Frequency: 41GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 81%

Shielding Effectiveness: >90dB

Voltage Power: 500V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000 26500 40000
Attenuation (dB/100m) 40.5 57.6 70.8 100.8 116.9 131.2 146.6 178.0 218.0 271.2
Avg.Power (kW) 0.567 0.399 0.325 0.228 0.197 0.175 0.157 0.129 0.105 0.085
K1= 1.267795
K2= 0.000440
Calculation = K1* √FMhz+K2*FMHz

Features & Advantages

Low Loss

Low VSWR

Bending, Shake, Torsion & Pull Resistance

Typical Applications

Aviation Electronics

Electronic Confrontation

Laboratory Test

RF Microwaves Device Test