Cable Construction Specifications
Description | Dimensions (mm) | Material | |
1-6 | TLC220 Cable | 2.40 | FEP |
7-8 | Protect Layer | 3.60 | SPC |
9-10 | Jacket | 4.80 | PTFE |
Mechanical & Environmental Specifications
Frequency Range: DC-67GTLZ
VSWR: ≤1.4@67GTLZ
Repeated bending: 100,000 times
Temperature Range: -55℃~+125℃
Electrical Specifications
Static Bend Radius: 30mm
Dynamic Bend Radius: 50mm
Mechanical Phase: ±7°
Amplitude Stability: ±0.1dB
Weight: 0.052Kg/m
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 | 67000 |
Attenuation (dB/100m) | 63.7 | 90.8 | 111.9 | 160.4 | 186.5 | 209.8 | 235.2 | 287.1 | 354.0 | 444.0 | 593.2 |
Avg. Power (kW) | 0.097 | 0.068 | 0.055 | 0.039 | 0.033 | 0.029 | 0.026 | 0.022 | 0.017 | 0.014 | 0.010 |
K1= | 1.975832 | ||||||||||
K2= | 0.001221 | ||||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Bending, Shake, Torsion & Pull resistance
Typical Applications
Laboratory Test
Anechoic Chambers
System Test
High-Precision Instruments Test
On-site Testing and Measurement