TLC220-KJ

Frequency Range: DC-67GTLZ
VSWR: ≤1.4@67GTLZ
Repeated bending: 100,000 times
Temperature Range: -55℃~+125℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Material
1-6 TLC220 Cable 2.40 FEP
7-8 Protect Layer 3.60 SPC
9-10 Jacket 4.80 PTFE

Mechanical & Environmental Specifications

Frequency Range: DC-67GTLZ

VSWR: ≤1.4@67GTLZ

Repeated bending: 100,000 times

Temperature Range: -55℃~+125℃

Electrical Specifications

Static Bend Radius: 30mm

Dynamic Bend Radius: 50mm

Mechanical Phase: ±7°

Amplitude Stability: ±0.1dB

Weight: 0.052Kg/m

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000 26500 40000 67000
Attenuation (dB/100m) 63.7 90.8 111.9 160.4 186.5 209.8 235.2 287.1 354.0 444.0 593.2
Avg. Power (kW) 0.097 0.068 0.055 0.039 0.033 0.029 0.026 0.022 0.017 0.014 0.010
K1= 1.975832
K2= 0.001221
Calculation= K1* √FMhz+K2*FMHz

Features & Advantages

Low Loss

Low VSWR

Bending, Shake, Torsion & Pull resistance

Typical Applications

Laboratory Test

Anechoic Chambers

System Test

High-Precision Instruments Test

On-site Testing and Measurement