TLC220

Static Bend Radius: 12mm
Dynamic Bend Radius: 24mm
Weight: 0.016Kg/m
Installation & Operating Temperature Range: -55℃~+165℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Material
1 Inner Conductor 0.50 Solid SPC
2 Dielectric 1.38 LD-PTFE
3 Inner Shield 1.54 SPC Strip
4 Interlayer 1.82 LD-PTFE
5 Outer Shield 2.17 SPC Braid
6 Jacket 2.40 Blue FEP or Custom

Mechanical & Environmental Specifications

Static Bend Radius: 12mm

Dynamic Bend Radius: 24mm

Weight: 0.016Kg/m

Installation & Operating Temperature Range: -55℃~+165℃

Electrical Specifications

Frequency Range: 67GTLZ

Cutoff Frequency: 82GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 81%

Shielding Effectiveness: >90dB

Voltage Power: 500V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000 26500 40000 67000
Attenuation (dB/100m) 63.7 90.8 111.9 160.4 186.5 209.8 235.2 287.1 354.0 444.0 593.2
Avg.Power (kW) 0.097 0.068 0.055 0.039 0.033 0.029 0.026 0.022 0.017 0.014 0.010
K1= 1.975832
K2= 0.001221
Calculation = K1* √FMhz+K2*FMHz

Features & Advantages

Low Loss

Low VSWR

Bending, Shake, Torsion & Pull Resistance

Typical Applications

Aviation Electronics

Electronic Confrontation

Laboratory Test

RF Microwaves Device Test