Cable Construction Specifications
Description | Dimensions (mm) | Material | |
1-6 | TLC220 Cable | 1.85 | FEP |
7-8 | Protect Layer | 2.70 | SPC |
9-10 | Jacket | 3.84 | PTFE |
Mechanical & Environmental Specifications
Frequency Range: DC-110GTLZ
VSWR: ≤1.5@110GTLZ
Repeated bending: 50,000 times
Temperature Range: -55℃~+125℃
Electrical Specifications
Static Bend Radius: 30mm
Dynamic Bend Radius: 50mm
Mechanical Phase: ±10°
Amplitude Stability: ±0.1dB
Weight: 0.033Kg/m
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 18000 | 26500 | 40000 | 67000 | 75000 | 110000 |
Attenuation (dB/100m) | 113.7 | 161.6 | 198.5 | 282.9 | 328.0 | 499.3 | 611.5 | 760.4 | 1002.7 | 1065.9 | 1314.3 |
Avg. Power (kW) | 0.039 | 0.027 | 0.022 | 0.016 | 0.014 | 0.009 | 0.007 | 0.006 | 0.004 | 0.004 | 0.003 |
K1= | 3.557846 | ||||||||||
K2= | 0.001221 | ||||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Bending, Shake, Torsion & Pull resistance
Typical Applications
Laboratory Test
Anechoic Chambers
System Test
High-Precision Instruments Test
On-site Testing and Measurement