Cable Construction Specifications
| Description | Dimensions (mm) | Material | |
| 1-6 | TLC220 Cable | 3.60 | FEP |
| 7-8 | Protect Layer | 5.10 | SPC |
| 9-10 | Jacket | 6.10 | PTFE |
Mechanical & Environmental Specifications
Frequency Range: DC-50GTLZ
VSWR: ≤1.35@50GTLZ
Repeated bending: 100,000 times
Temperature Range: -55℃~+125℃
Electrical Specifications
Static Bend Radius: 30mm
Dynamic Bend Radius: 60mm
Mechanical Phase: ±7°
Amplitude Stability: ±0.05dB
Weight: 0.095Kg/m
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
| Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 | 50000 |
| Attenuation (dB/100m) | 48.1 | 68.3 | 83.9 | 119.4 | 138.4 | 155.2 | 173.4 | 210.2 | 257.1 | 319.2 | 359.2 |
| Avg. Power (kW) | 0.506 | 0.356 | 0.290 | 0.204 | 0.176 | 0.157 | 0.140 | 0.116 | 0.095 | 0.076 | 0.068 |
| K1= | 1.507809 | ||||||||||
| K2= | 0.000440 | ||||||||||
| Calculation= | K1* √FMhz+K2*FMHz | ||||||||||
Features & Advantages
Low Loss
Low VSWR
Bending, Shake, Torsion & Pull resistance
Typical Applications
Laboratory Test
Anechoic Chambers
System Test
High-Precision Instruments Test
On-site Testing and Measurement