Cable Construction Specifications
Description | Dimensions (mm) | Material | |
1-6 | TLC220 Cable | 4.20 | FEP |
7-8 | Protect Layer | 5.75 | SPC |
9-10 | Jacket | 6.70 | PTFE |
Mechanical & Environmental Specifications
Frequency Range: DC-40GTLZ
VSWR: ≤1.3@40GTLZ
Repeated bending: 100,000 times
Temperature Range: -55℃~+125℃
Electrical Specifications
Static Bend Radius: 40mm
Dynamic Bend Radius: 70mm
Mechanical Phase: ±7°
Amplitude Stability: ±0.05dB
Weight: 0.110Kg/m
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 | 26500 | 40000 |
Attenuation (dB/100m) | 40.5 | 57.6 | 70.8 | 100.8 | 116.9 | 131.2 | 146.6 | 178.0 | 218.0 | 271.2 |
Avg. Power (kW) | 0.567 | 0.399 | 0.325 | 0.228 | 0.197 | 0.175 | 0.157 | 0.129 | 0.105 | 0.085 |
K1= | 1.267795 | |||||||||
K2= | 0.000440 | |||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
Low VSWR
Bending, Shake, Torsion & Pull resistance
Typical Applications
Laboratory Test
Anechoic Chambers
System Test
High-Precision Instruments Test
On-site Testing and Measurement