Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 1.29 | Solid SPC |
2 | Dielectric | 3.85 | LD-PTFE |
3 | Outer Conductor | 4.05 | SPC Strip |
4 | Outer Shield | 4.62 | SPC Braid |
5 | Jacket | 5.20 | Blue FEP |
Mechanical & Environmental Specifications
Static Bend Radius: 26mm
Dynamic Bend Radius: 52mm
Weight: 0.066Kg/m
Installation & Operating Temperature Range: -55℃~+165℃
Electrical Specifications
Frequency Range: 26GTLZ
Cutoff Frequency: 28GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 76%
Shielding Effectiveness: >90dB
Voltage Power: 1000V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Attenuation (dB/100m) | 25.0 | 35.6 | 44.0 | 63.2 | 73.7 | 83.0 | 93.1 | 114.0 | 141.1 |
Avg. Power (kW) | 0.749 | 0.524 | 0.425 | 0.296 | 0.254 | 0.225 | 0.201 | 0.164 | 0.132 |
K1= | 0.770610 | ||||||||
K2= | 0.000591 | ||||||||
Calculation= | K1* √FMhz+K2*FMHz |
Features & Advantages
Low Loss
High power
Low Passive Intermodulation (-155dbc)
Cost-effective
Typical Applications
Aviation Electronics
Electronic Confrontation
Wireless Telecommunication Base Station Interconnection