Cable Construction Specifications
Description | Dimensions (mm) | Materials | |
1 | Inner Conductor | 0.94 | Solid SPC |
2 | Dielectric | 2.98 | Solid PTFE |
3 | Inner Shield | 3.25 | SPC Strip |
4 | Interlayer | 3.40 | Aluminum Foil |
5 | Outer Shield | 3.95 | SPC Braid |
6 | Jacket | 4.88 | FEP |
Mechanical & Environmental Specifications
Static Bend Radius: 24mm
Dynamic Bend Radius: 48mm
Weight: 0.058Kg/m
Installation & Operating Temperature Range: -55℃~+125℃
Mechanical Phase Change: ±1°/GHz
Electrical Specifications
Frequency Range: 18GTLZ
Cutoff Frequency: 40GTLZ
Characteristic Impedance: 50Ω
Velocity of Propagation: 70%
Shielding Effectiveness: >90dB
Voltage Power: 100V,DC
Attenuation (Typical value @ +25℃ & VSWR=1.0)
Power (Typical value @ +40℃ & atmospheric pressure)
Frequency (MHz) | 1000 | 2000 | 3000 | 6000 | 8000 | 10000 | 12400 | 18000 |
Attenuation (dB/100m) | 40.0 | 58.9 | 74.3 | 112.1 | 133.6 | 153.5 | 176.0 | 224.0 |
Avg. Power (kW) | 0.488 | 0.332 | 0.263 | 0.174 | 0.146 | 0.127 | 0.111 | 0.087 |
K1= | 1.141732 | |||||||
K2= | 0.003937 | |||||||
Calculation= | K1* √FMhz+K2*FMHz |