TLZ800

Static Bend Radius: 40mm
Dynamic Bend Radius: 80mm
Weight: 0.116Kg/m
Installation & Operating Temperature Range: -55℃~+85℃

Our contacts:

Phone: 7183408296
Email: info@raelsys.com
Category:

Cable Construction Specifications

Description Dimensions (mm) Materials
1 Inner Conductor 1.88 Stranded SPC
2 Dielectric 5.50 LD-PTFE
3 Outer Conductor 5.74 SPC Strir
4 Outer Shield 6.31 SPC Braid
5 Jacket 8.00 Blue PUR or custom

Mechanical & Environmental Specifications

Static Bend Radius: 40mm

Dynamic Bend Radius: 80mm

Weight: 0.116Kg/m

Installation & Operating Temperature Range: -55℃~+85℃

Electrical Specifications

Frequency Range: 18GTLZ

Cutoff Frequency: 20GTLZ

Characteristic Impedance: 50Ω

Velocity of Propagation: 76%

Shielding Effectiveness: >90dB

Voltage Power: 1700V,DC

Attenuation (Typical value @ +25℃ & VSWR=1.0)

Power (Typical value @ +40℃ & atmospheric pressure)

Frequency (MHz) 1000 2000 3000 6000 8000 10000 12400 18000
Attenuation (dB/100m) 18.2 26.7 33.8 50.9 60.7 69.8 80.0 101.9
Avg. Power (kW) 0.327 0.222 0.176 0.117 0.098 0.085 0.074 0.058
K1= 0.517315
K2= 0.001806
Calculation= K1* √FMhz+K2*FMHz

Features & Advantages

Multi-stranded, Super-Flexible

Resistance to Harsh Environments

Typical Applications

Cabinet Internal Interconnection

Phased Array Radar Array Free Connection

Module Internal Interconnection

Small, Complex and Installation Space