Used Arbitrary Waveform Generator SR DS345

It generates many standard waveforms with excellent frequency resolution (1 µHz), including: sine waves and square waves at frequencies up to 30.2 MHz, and triangle and ramp waveforms up to 100 kHz.

Our contacts:

Phone: 7183408296
Email: info@raelsys.com

The Stanford Research Systems (SRS) DS345 Function and Arbitrary Waveform Generator is a full-featured, 30 MHz instrument that uses an innovative Direct Digital Synthesis (DDS) architecture. It generates many standard waveforms with excellent frequency resolution (1 µHz), including: sine waves and square waves at frequencies up to 30.2 MHz, and triangle and ramp waveforms up to 100 kHz. In addition to the standard waveforms, the unit also provides a wideband (10 MHz) white noise source and has versatile modulation capabilities including AM, FM, Burst, PM and frequency sweeps. It also generates arbitrary waveforms with a fast 40 Msample/s update rate and 12-bit vertical resolution. A 10 MHz rear-panel input allows the DS345 to be synchronized to an external timebase. A 10 MHz rear-panel output allows multiple DS345’s to be phase locked.

Features and Specifications of:

●1 µHz to 30.2 MHz frequency range

●1 µHz frequency resolution

●Sine, square, ramp, triangle and noise

●Phase continuous frequency sweeps

●AM, FM, burst and phase modulation

●16,300 point arbitrary waveforms

●10 MHz reference input

●Optional RS-232 and GPIB interfaces

●Frequency Range:

■Sine: 

■Max Frequency:  30.2 MHz

■Resolution:  1 µHz

■Square: 

■Max Frequency:  30.2 MHz

■Resolution:  1 µHz

■Ramp: 

■Max Frequency:  100 kHz

■Resolution:  1 µHz

■Triangle: 

■Max Frequency:  100 kHz

■Resolution:  1 µHz

■Noise: 

■Max Frequency:  10 MHz

■Resolution:  (Gaussian weighting)

■Arbitrary:

■Max Frequency:  10 MHz

■Resolution:  40 MHz/n (sample rate)

●Output:

■Source Impedance:  50 O

■Grounding:  Output may float up to ±40 V (AC + DC) relative to earth ground

●Amplitude:

■Range:               0.01 to 10 Vpp (50 O), 20 Vpp (Hi-Z)

■Resolution:          3 digits (DC offset = 0 V)

■Sine Wave Accuracy (0 V DC offset):

■5 to 10 Vpp: 

■±0.2 dB (1 µHz to 20 MHz)

■±0.3 dB (20 MHz to 30.2 MHz)

■0.01 to 5 Vpp:

■±0.4 dB(1 µHz to 20 MHz)

■±0.5 dB (20 MHz to 30.2 MHz)

■Square Wave Accuracy:

■5 to 10 Vpp:

■±3 % (1 µHz to 100 kHz)

■±6 % (100 kHz to 20 MHz)

■±15 % (20 MHz to 30.2 MHz)

■0.01 to 5 Vpp:

■±5 % (1 µHz to 100 kHz)

■±8 % (100 kHz to 20 MHz)

■±18 % (20 MHz to 30.2 MHz)

■Triangle, Ramp, Arbitrary Accuracy:

■±3 % (>5 Vpp)

■±5 % (

●DC Offset:

■Range:  ±5 V (limited such that |VAC peak| + |VDC| < 5 V)

■Resolution:  3 digits (VAC = 0)

■Accuracy: 

■1.5 % of setting + 0.2 mV (DC only) 

■±0.8 mV to ±80 mV, depending on AC and DC settings

●Sine Wave:

■Spurious Components: 

■Phase Noise: 

■Sub-Harmonic: 

■Harmonic Distortion:

■Level:

■Level:

■Level:

■Level:

●Square Wave:

■Rise/Fall Time: 

■Asymmetry:  

■Overshoot:  

●Ramps, Triangle and Arbitrary Waveforms:

■Rise/Fall Time:  45 ns (10 MHz Bessel filter)

■Linearity:  ±0.5 % of full-scale output

■Settling Time: 

●Arbitrary Waveforms:

■Sample Rate:  40 MHz/N, N = 1 to 234-1

■Memory Length:   8 to 16,300 points

■Resolution:   12 bits (0.025 % of full scale)

●Phase:

■Range:  ±7199.999° with respect to arbitrary starting phase

■Resolution:  0.001°

●Amplitude Modulation:

■Source:  Internal (sine, square, triangle or ramp) or External

■Depth:  0 to 100 % AM or DSBSC

■Rate:  0.001 Hz to 10 kHz internal, 15 kHz max external

■Distortion: 

■DSB Carrier: 

■External Input:  ±5 V for 100 % modulation, 100 kO impedance, 15 kHz bandwidth

●Frequency Modulation:

■Source:  Internal (sine, square, triangle, ramp or arbitrary)

■Rate:  0.001 Hz to 10 kHz

■Span:  1 mHz to 30.2 MHz (100 kHz for triangle, ramp)

●Phase Modulation:

■Source:  Internal (sine, square, triangle, ramp)

■Rate:  0.001 Hz to 10 kHz

■Span:  ±7199.999°

●Frequency Sweep:

■Type:  Linear or log, phase continuous

■Waveform:  Up, down, up-down, single sweep

■Time:  0.001 s to 1000 s

■Span:  1 mHz to 30.2 MHz (to 100 kHz for triangle, ramp)

■Markers:  Two markers may be set at any sweep point (TTL output)

■Sweep Output:  0 to 10 V linear ramp signal, synchronized to sweep

●Burst Modulation:

■Waveform:  Any waveform except noise may be burst modulated

■Frequency:  Sine, square to 1 MHz

Triangle, ramp to 100 kHz

Arbitrary to 40 MHz sample rate

■Count:  1 to 30,000 cycles/burst (1 µs to 500 s burst time limits)

●Trigger Generator:

■Source:  Single, Internal, External, Line

■Rate (Internal):  0.001 Hz to 10 kHz (2-digit resolution)

■External Trigger:  Positive or negative edge, TTL

■Output:  TTL level

●Standard Timebase:

■Accuracy:  ±5 ppm (20 °C to 30 °C)

■Aging: 5 ppm/year

■Input:  10 MHz/N ± 2 ppm (N = 1 to 8) 1 Vpp minimum input level

■Output:  10 MHz, >1 Vpp sine into 50 O

●General:

■Interfaces:  Optional RS-232 (300 to 19.2 kbaud, DCE) and GPIB with DOS based arbitrary waveform software (AWC). All instrument functions are controllable over the interfaces.

■Non-Volatile Memory:  Nine sets of instrument settings can be saved and recalled

■Power:  50 W, 100/120/220/240 VAC, 50/60 Hz